10.11

Transformers

Chapter contents: Chapter 10: Magnetism

Transformers do what their name implies—they transform voltages from one value to another. For example, many cell phones, laptops, video games, and power tools and small appliances have a transformer built into their plug-in unit (like that in Figure 10.11.1) that changes 120 V or 240 V AC into whatever voltage the device uses. Transformers are also used at several points in the power distribution systems, such as illustrated in Figure 10.11.2. Power is sent long distances at high voltages, because less current is required for a given amount of power, and this means less line loss, as was discussed previously. But high voltages pose greater hazards, so that transformers are employed to produce lower voltage at the user’s location.
A photo graph of two plug in transformers operated on voltages other than common one hundred twenty volt AC.
Figure 10.11.1. The plug-in transformer has become increasingly familiar with the proliferation of electronic devices that operate on voltages other than common 120 V AC. Most are in the 3 to 12 V range. (credit: Shop Xtreme)
The figure shows a transmission power system. It shows the various stages in a power transmission system from the power plant to the house hold with the help of images. The first image is of a power plant. The voltage generated is at twelve volts. This voltage is shown to pass on to a step up transformer through cables. From the step up transformer the current passes through a high voltage transmission line at four hundred kilo volt. The high voltage transmission line is shown passing on three towers. The current is then passed to a step down transformer substation. The current is step down to twelve volts. This is now passed through power transmission lines on poles. This current reaches a step down transformer which is fixed on a pole. Here the voltage is further stepped down to two hundred forty volts. Current is then supplied to an individual household at two hundred forty volts.
Figure 10.11.2. Transformers change voltages at several points in a power distribution system. Electric power is usually generated at greater than 10 kV, and transmitted long distances at voltages over 200 kV—sometimes as great as 700 kV—to limit energy losses. Local power distribution to neighborhoods or industries goes through a substation and is sent short distances at voltages ranging from 5 to 13 kV. This is reduced to 120, 240, or 480 V for safety at the individual user site.
The type of transformer considered in this text—see Figure 10.11.3—is based on Faraday’s law of induction and is very similar in construction to the apparatus Faraday used to demonstrate magnetic fields could cause currents. The two coils are called the primary and secondary coils. In normal use, the input voltage is placed on the primary, and the secondary produces the transformed output voltage. Not only does the iron core trap the magnetic field created by the primary coil, its magnetization increases the field strength. Since the input voltage is AC, a time-varying magnetic flux is sent to the secondary, inducing its AC output voltage.
The figure shows a simple transformer with two coils wound on either sides of a laminated ferromagnetic core. The set of coil on left side of the core is marked as the primary and there number is given as N p. The voltage across the primary is given by V p. The set of coil on right side of the core is marked as the secondary and there number is represented as N s. The voltage across the secondary is given by V s. A symbol of the transformer is also shown below the diagram. It consists of two inductor coils separated by two equal parallel lines representing the core.
Figure 10.11.3. A typical construction of a simple transformer has two coils wound on a ferromagnetic core that is laminated to minimize eddy currents. The magnetic field created by the primary is mostly confined to and increased by the core, which transmits it to the secondary coil. Any change in current in the primary induces a current in the secondary.
For the simple transformer shown in Figure 10.11.3, the output voltage Vs depends almost entirely on the input voltage Vp and the ratio of the number of loops in the primary and secondary coils. Faraday’s law of induction for the secondary coil gives its induced output voltage Vs to be
Vs=NsΔΦΔt,
(10.11.1)
where Ns is the number of loops in the secondary coil and ΔΦ/ Δt is the rate of change of magnetic flux. The cross-sectional area of the coils is the same on either side, as is the magnetic field strength, and so ΔΦ/Δt is the same on either side. The input primary voltage Vp is also related to changing flux by
Vp=NpΔΦΔt.
(10.11.2)
The reason for this is a little more subtle. Lenz’s law tells us that the primary coil opposes the change in flux caused by the input voltage Vp, hence the minus sign. Assuming negligible coil resistance, Kirchhoff’s loop rule tells us that the induced voltage exactly equals the input voltage. Taking the ratio of these last two equations yields a useful relationship:
VsVp=NsNp.
(10.11.3)
This is known as the transformer equation, and it simply states that the ratio of the secondary to primary voltages in a transformer equals the ratio of the number of loops in their coils.
The output voltage of a transformer can be less than, greater than, or equal to the input voltage, depending on the ratio of the number of loops in their coils. Some transformers even provide a variable output by allowing connection to be made at different points on the secondary coil. A step-up transformer is one that increases voltage, whereas a step-down transformer decreases voltage. Assuming, as we have, that resistance is negligible, the electrical power output of a transformer equals its input. This is nearly true in practice—transformer efficiency often exceeds 99%. Equating the power input and output,
Pp=IpVp=IsVs=Ps.
(10.11.4)
Rearranging terms gives
VsVp=IpIs.
(10.11.5)
Combining this with VsVp=NsNp, we find that
IsIp=NpNs
(10.11.6)
is the relationship between the output and input currents of a transformer. So if voltage increases, current decreases. Conversely, if voltage decreases, current increases.
Example 10.11.1

Calculating Characteristics of a Step-Up Transformer

A portable x-ray unit has a step-up transformer, the 120 V input of which is transformed to the 100 kV output needed by the x-ray tube. The primary has 50 loops and draws a current of 10.00 A when in use. (a) What is the number of loops in the secondary? (b) Find the current output of the secondary.
Strategy and Solution for (a)
We solve VsVp=NsNp for Ns, the number of loops in the secondary, and enter the known values. This gives
Ns=NpVsVp=(50)100,000 V120 V=4.17×104.
(10.11.7)
Discussion for (a)
A large number of loops in the secondary (compared with the primary) is required to produce such a large voltage. This would be true for neon sign transformers and those supplying high voltage inside TVs and CRTs.
Strategy and Solution for (b)
We can similarly find the output current of the secondary by solving IsIp=NpNs for Is and entering known values. This gives
Is=IpNpNs=(10.00 A)504.17×104=12.0 mA.
(10.11.8)
Discussion for (b)
As expected, the current output is significantly less than the input. In certain spectacular demonstrations, very large voltages are used to produce long arcs, but they are relatively safe because the transformer output does not supply a large current. Note that the power input here is Pp=IpVp=(10.00A)(120V)=1.20kW. This equals the power output Pp=IsVs=(12.0mA)(100kV)=1.20kW, as we assumed in the derivation of the equations used.
Example 10.11.2

Calculating Characteristics of a Step-Down Transformer

A battery charger meant for a series connection of ten nickel-cadmium batteries needs to have a 15.0 V output to charge the batteries. It uses a step-down transformer with a 200-loop primary and a 120 V input. (a) How many loops should there be in the secondary coil? (b) If the charging current is 16.0 A, what is the input current?
Strategy and Solution for (a)
You would expect the secondary to have a small number of loops. Solving VsVp=NsNp for Ns and entering known values gives
Ns=NpVsVp=(200)15.0 V120 V=25.
(10.11.9)
Strategy and Solution for (b)
The current input can be obtained by solving IsIp=NpNs for Ip and entering known values. This gives
Ip=IsNsNp=(16.0 A)25200=2.00 A.
(10.11.10)
Discussion
The number of loops in the secondary is small, as expected for a step-down transformer. We also see that a small input current produces a larger output current in a step-down transformer. When transformers are used to operate large magnets, they sometimes have a small number of very heavy loops in the secondary. This allows the secondary to have low internal resistance and produce large currents. Note again that this solution is based on the assumption of 100% efficiency—or power out equals power in (Pp=Ps)—reasonable for good transformers. In this case the primary and secondary power is 240 W. (Verify this for yourself as a consistency check.) Note that the Ni-Cd batteries need to be charged from a DC power source (as would a 12 V battery). So the AC output of the secondary coil needs to be converted into DC. This is done using something called a rectifier, which uses devices called diodes that allow only a one-way flow of current.

Section Summary

  • Transformers use induction to transform voltages from one value to another.
  • For a transformer, the voltages across the primary and secondary coils are related by
    VsVp=NsNp,
    (10.11.11)
    where Vp and Vs are the voltages across primary and secondary coils having Np and Ns turns.
  • The currents Ip and Is in the primary and secondary coils are related by IsIp=NpNs.
  • A step-up transformer increases voltage and decreases current, whereas a step-down transformer decreases voltage and increases current.

Problems & Exercises

Exercise 35
A plug-in transformer supplies 9.00 V to a video game system. (a) How many turns are in its secondary coil, if its input voltage is 120 V and the primary coil has 400 turns? (b) What is its input current when its output is 1.30 A?
Solution
(a) 30.0
(b) 9.75×102A
Exercise 36
An American traveler in New Zealand carries a transformer to convert New Zealand’s standard 240 V to 120 V so that she can use some small appliances on her trip. (a) What is the ratio of turns in the primary and secondary coils of her transformer? (b) What is the ratio of input to output current? (c) How could a New Zealander traveling in the United States use this same transformer to power her 240 V appliances from 120 V?
Exercise 37
A digital recorder uses a plug-in transformer to convert 120 V to 12.0 V, with a maximum current output of 200 mA. (a) What is the current input? (b) What is the power input? (c) Is this amount of power reasonable for a small appliance?
Solution
(a) 20.0 mA
(b) 2.40 W
(c) Yes, this amount of power is quite reasonable for a small appliance.
Exercise 38
(a) What is the voltage output of a transformer used for rechargeable flashlight batteries, if its primary has 500 turns, its secondary 4 turns, and the input voltage is 120 V? (b) What input current is required to produce a 4.00 A output? (c) What is the power input?
Exercise 39
(a) The plug-in transformer for a laptop computer puts out 7.50 V and can supply a maximum current of 2.00 A. What is the maximum input current if the input voltage is 240 V? Assume 100% efficiency. (b) If the actual efficiency is less than 100%, would the input current need to be greater or smaller? Explain.
Solution
(a) 0.063 A
(b) Greater input current needed.
Exercise 40
A multipurpose transformer has a secondary coil with several points at which a voltage can be extracted, giving outputs of 5.60, 12.0, and 480 V. (a) The input voltage is 240 V to a primary coil of 280 turns. What are the numbers of turns in the parts of the secondary used to produce the output voltages? (b) If the maximum input current is 5.00 A, what are the maximum output currents (each used alone)?
Exercise 41
A large power plant generates electricity at 12.0 kV. Its old transformer once converted the voltage to 335 kV. The secondary of this transformer is being replaced so that its output can be 750 kV for more efficient cross-country transmission on upgraded transmission lines. (a) What is the ratio of turns in the new secondary compared with the old secondary? (b) What is the ratio of new current output to old output (at 335 kV) for the same power? (c) If the upgraded transmission lines have the same resistance, what is the ratio of new line power loss to old?
Solution
(a) 2.2
(b) 0.45
(c) 0.20, or 20.0%
Exercise 42
If the power output in the previous problem is 1000 MW and line resistance is 2.00 Ω, what were the old and new line losses?
transformer
a device that transforms voltages from one value to another using induction
transformer equation
the equation showing that the ratio of the secondary to primary voltages in a transformer equals the ratio of the number of loops in their coils; VsVp=NsNp
step-up transformer
a transformer that increases voltage
step-down transformer
a transformer that decreases voltage